Separation of Fullerenes Metallo-fullerenes | ||
Buckyprep-D |
- For preparative separation of derivatized fullerenes
- For separation of derivatized fullerenes such as C60 indene used for organic thin-film solar cell
MATERIAL CHARACTERISTICS | |
COSMOSIL Buckyprep-D | |
Silicagel | high purity porous spherical silica gel |
Average particle size | 5µm |
Average pore size | approx. 120Å |
Specific surface area | approx. 300m2/g |
Bonded Phase | |
Bonded phase | Nitro-carbazoyl group |
End capping treatment | Noear-perfect |
Feature | For separation of fullerene derivatives |
Application of C60 Indene |
Buckyprep-D offers improved separation for C60 indene, a derivatized fullerenes, that has received much attention as the n-type semiconductor material of organic thin-film solar cell.
COSMOSIL Buckyprep-D | COSMOSIL Buckyprep |
Data courtesy of Yusuke Tajima, Dr. Sci.
Organic Optoelectronics Laboratory, RIKEN (Institute of Physics and Chemistry)
Column size: 4.6mmI.D.×250mm; Mobile phase: toluene; Flow rate: 1.0 ml/min.; Detection: UV 325 nm; Temperature: 30 C; Sample: C60[Indene]2 (1.0mg/ml)
Comparison with Conventional Buckyprep Column |
Buckyprep-D retains derivatized fullerenes longer than C60. Therefore it is more suitable for preparative separation of derivatized fullerenes than conventional Buckyprep column.
5C18-MS-II | Buckyprep-D | Buckyprep |
Column size: 4.6mmI.D.×250mm; Mobile phase: toluene; Flow rate: 1.0 ml/min.; Detection: UV 325 nm; Temperature: 30 C
Adjustment of Retention by Mobile Phase
Comparison of Each Solvent
Adding hexane or heptane to toluene increases retention on Buckyprep-D, while adding methanol or acetonitrile decreases retention. The effect of solvents on retention is the opposite of the conventional Buckyprep column.
Table. Comparison of percentage of retention ratio of each solvent on Buckyprep-D
Y-axis: Percentage of capacity factor k’ when it is 100% toluene
X-axis: 10% of each solvent added into toluene
Adding Methanol Decreases Retention
Retention may decrease when a polar solvent is added on Buckyprep-D. For example, by increasing the methanol concentration to 1%, the retention dramatically decreases.
Buckyprep-D | |
Column size: | 4.6 mm I.D. x 250 mm |
Flow rate: | 1.0 ml/min |
Temperature: | 30°C |
Detection: | UV 325 nm |
Sample: | [6,6]-Diphenyl-C62 Bis(Butyric Acid Methyl Ester) (0.5mg/ml) |
Inj. Vol: | 5.0 µl |
Solution for Too Strong Retention on Buckyprep-D
If the retention of derivatized fullerens on Buckyprep-D is too strong, shorten column length or add additives in toluene to decrease retention.
Using 50 mm Length Column
Buckyprep-D | |
Column size: | 4.6 mm I.D. x 50 mm |
Mobile phase: | Toluene |
Flow rate: | 1.0 ml/min |
Temperature: | 30°C |
Detection: | UV 325 nm |
Sample: | [6,6]-Diphenyl-C62 Bis (Butyric Acid Methyl Ester) [Bis[60]PCBM] (0.50mg/ml) |
Inj. Vol: | 10 µl |
Adding Methanol
Buckyprep-D | |
Column size: | 4.6 mm I.D. x 250 mm |
Mobile phase: | Methanol/ Toluene = 1/99 |
Flow rate: | 1.0 ml/min |
Temperature: | 30°C |
Detection: | UV 325 nm |
Sample: | Tris [C60] PCBM |
Sample cpnc: | 1.0 mg/ml |
Inj. Vol: | 10.0 µl |
Features of Each Solvent for Fullerenes Separation
Buckyprep | Buckyprep | Solubility of C60 (mg/ml) |
Toluene | The most commonly used solvent | 3.2 |
n-hexane | 0.046 | |
n-heptane | Weaker eluent than toluene | – |
Methanol* | 0.001 | |
2-propanol* | – | |
Acetonitrile* | Weaker eluent than toluene. Recommended as a wash solvent for Buckyprep-D | 0.018 |
Chlorobenzene | Stronger eluent than toluene | 7.0 |
o-dichlorobenzene | Stronger eluent than chlorobenzene | 27 |
1,2,4-trichlorobenzene | The strongest eluent. Recommended as a wash solvent | 21.3 |
* These are stronger eluent on Buckyprep-D, opposite to Buckyprep.
Attention:
Use HPLC Grade solvent or solvents after filtration or distillation. Except for alkali aqueous and strong acidic solutions, other solvents can be used (water-free pyridine and others). Depending on solvents, pay attention to high pressure caused by high solvent viscosity.
Note:
Baseline of Bukyprep-D is less stable relative to other fullerene columns. To stabilize baseline, let acetonitrile run through for 10 minutes before analysis.
COSMOSIL BUCKYPREP-D
Item | Catalog | Price ($U.S.) | Buy |
---|---|---|---|
Buckyprep-D Guard Column, 4.6 mm I.D. x 10 mm | 09611-01 | $494.00 | Add to cart |
Buckyprep-D Packed Column, 10 mm I.D. x 250 mm | 09650-91 | $6,479.00 | Add to cart |
Buckyprep-D Guard Column, 10 mm I.D. x 20 mm | 09613-81 | $1,483.00 | Add to cart |
Buckyprep-D Guard Column, 20 mm I.D. x 50 mm | 09614-71 | $6,067.00 | Add to cart |
Buckyprep-D Packed Column, 10 mm I.D. x 50 mm | 09648-41 | $3,554.00 | Add to cart |
Buckyprep-D Packed Column, 4.6 mm I.D. x 250 mm | 09647-51 | $2,009.00 | Add to cart |
Buckyprep-D Packed Column, 4.6 mm I.D. x 50 mm | 09646-61 | $896.00 | Add to cart |
Learn more about Carbon 60 at SES Research